{"id":52463,"date":"2026-01-29T18:50:34","date_gmt":"2026-01-29T18:50:34","guid":{"rendered":"https:\/\/automatyczni.sklep.pl\/zaslepka-zaworu-sec-pressure-reg-valve-6dct450\/"},"modified":"2026-09-23T12:48:11","modified_gmt":"2026-09-23T12:48:11","slug":"zaslepka-zaworu-sec-pressure-reg-valve-6dct450","status":"publish","type":"product","link":"https:\/\/automatyczni.sklep.pl\/en\/zaslepka-zaworu-sec-pressure-reg-valve-6dct450\/","title":{"rendered":"valve cap. Pressure reg. Valve 6DCT450"},"content":{"rendered":"<h2 data-start=\"42\" data-end=\"103\">Valve plug of the Secondary Pressure Regulator Valve 6DCT450<\/h2>\n<p data-start=\"105\" data-end=\"119\">SKU: MPS6.VA15<\/p>\n<hr data-start=\"121\" data-end=\"124\">\n<h3 data-start=\"126\" data-end=\"143\">Product description<\/h3>\n<p data-start=\"144\" data-end=\"421\">valve plug <strong data-start=\"160\" data-end=\"198\">Secondary pressure regulator valve<\/strong> For automatic dual-clutch gearbox <strong data-start=\"260\" data-end=\"278\">MPS6 \/ 6DCT450<\/strong>. The element mounted in the gearbox hydraulics (mechatronics) block is responsible for closing the secondary oil pressure control valve channel.<\/p>\n<p data-start=\"423\" data-end=\"566\">Used during hydraulic repairs, valve system modifications or when the factory secondary pressure control valve is replaced\/removed.<\/p>\n<p data-start=\"568\" data-end=\"581\">New product.<\/p>\n<hr data-start=\"583\" data-end=\"586\">\n<h3 data-start=\"588\" data-end=\"607\">master data<\/h3>\n<ul data-start=\"608\" data-end=\"836\">\n<li data-start=\"608\" data-end=\"639\">\n<p data-start=\"610\" data-end=\"639\">Box type: MPS6 \/ 6DCT450<\/p>\n<\/li>\n<li data-start=\"640\" data-end=\"679\">\n<p data-start=\"642\" data-end=\"679\">Box type: dual-clutch (DCT)<\/p>\n<\/li>\n<li data-start=\"680\" data-end=\"731\">\n<p data-start=\"682\" data-end=\"731\">Item Type: Hydraulic Valve Cap<\/p>\n<\/li>\n<li data-start=\"732\" data-end=\"777\">\n<p data-start=\"734\" data-end=\"777\">Valve: Secondary Pressure Valve Regulator<\/p>\n<\/li>\n<li data-start=\"778\" data-end=\"821\">\n<p data-start=\"780\" data-end=\"821\">Material: Metal (precisely machined)<\/p>\n<\/li>\n<li data-start=\"822\" data-end=\"836\">\n<p data-start=\"824\" data-end=\"836\">Condition: New<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"838\" data-end=\"841\">\n<h3 data-start=\"843\" data-end=\"859\">Application<\/h3>\n<p data-start=\"860\" data-end=\"882\"><strong data-start=\"860\" data-end=\"880\">Gearbox:<\/strong><\/p>\n<ul data-start=\"883\" data-end=\"903\">\n<li data-start=\"883\" data-end=\"891\">\n<p data-start=\"885\" data-end=\"891\">MPS6<\/p>\n<\/li>\n<li data-start=\"892\" data-end=\"903\">\n<p data-start=\"894\" data-end=\"903\">6DCT450<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"905\" data-end=\"1066\">Application depending on the controller version, market and configuration of hydraulics.<br data-start=\"983\" data-end=\"986\"><br \/>\nRecommended verification of compliance with the technical documentation of the box before assembly.<\/p>\n<hr data-start=\"1068\" data-end=\"1071\">\n<h3 data-start=\"1073\" data-end=\"1096\">Commercial information<\/h3>\n<ul data-start=\"1097\" data-end=\"1219\">\n<li data-start=\"1097\" data-end=\"1113\">\n<p data-start=\"1099\" data-end=\"1113\">New product<\/p>\n<\/li>\n<li data-start=\"1114\" data-end=\"1154\">\n<p data-start=\"1116\" data-end=\"1154\">Sold as a single plug<\/p>\n<\/li>\n<li data-start=\"1155\" data-end=\"1219\">\n<p data-start=\"1157\" data-end=\"1219\">Designed for professional repair of DCT transmission hydraulics<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1221\" data-end=\"1224\">\n<h3 data-start=\"1226\" data-end=\"1246\">Important information<\/h3>\n<\/p>\n<ul data-start=\"1247\" data-end=\"1608\">\n<li data-start=\"1247\" data-end=\"1322\">\n<p data-start=\"1249\" data-end=\"1322\">The product is intended for service and repair applications only.<\/p>\n<\/li>\n<li data-start=\"1323\" data-end=\"1391\">\n<p data-start=\"1325\" data-end=\"1391\">Installation requires knowledge of the MPS6 \/ 6DCT450 transmission hydraulics.<\/p>\n<\/li>\n<li data-start=\"1392\" data-end=\"1472\">\n<p data-start=\"1394\" data-end=\"1472\">Incorrect use may affect the operating pressure of the gearbox.<\/p>\n<\/li>\n<li data-start=\"1473\" data-end=\"1608\">\n<p data-start=\"1475\" data-end=\"1608\">after interfering with the gearbox hydraulics <strong data-start=\"1517\" data-end=\"1548\">Adaptation may be required<\/strong> and control of pressure parameters using diagnostics.<\/p>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>ZA\u015aLEPKA ZAWORU SECONDARY PRESSURE REGULATOR VALVE 6DCT450 SKU: MPS6.VA15 Opis produktu Za\u015blepka zaworu Secondary Pressure Regulator Valve przeznaczona do automatycznej,<\/p>","protected":false},"featured_media":52461,"template":"","meta":{"_uag_custom_page_level_css":""},"product_brand":[],"product_cat":[3159,3160,3164,70],"product_tag":[],"class_list":["post-52463","product","type-product","status-publish","has-post-thumbnail","product_cat-ford","product_cat-mazda","product_cat-powershift-6dct450-6dct451-mps6-6dct470-sps6","product_cat-producenci-skrzyn-automatycznych","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"uagb_featured_image_src":{"full":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d.png",1000,1000,false],"thumbnail":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d-150x150.png",150,150,true],"medium":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d-300x300.png",300,300,true],"medium_large":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d-768x768.png",768,768,true],"large":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d.png",1000,1000,false],"1536x1536":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d.png",1000,1000,false],"2048x2048":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d.png",1000,1000,false],"trp-custom-language-flag":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d-12x12.png",12,12,true],"gform-image-choice-sm":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d.png",300,300,false],"gform-image-choice-md":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d.png",400,400,false],"gform-image-choice-lg":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d.png",600,600,false],"mailpoet_newsletter_max":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d.png",1000,1000,false],"woocommerce_thumbnail":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d-350x350.png",350,350,true],"woocommerce_single":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d-800x800.png",800,800,true],"woocommerce_gallery_thumbnail":["https:\/\/automatyczni.sklep.pl\/wp-content\/uploads\/2026\/01\/eeb1739a57bf61e744d6ae40f160622d-300x300.png",300,300,true]},"uagb_author_info":{"display_name":"brancu123321","author_link":"https:\/\/automatyczni.sklep.pl\/en\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"ZA\u015aLEPKA ZAWORU SECONDARY PRESSURE REGULATOR VALVE 6DCT450 SKU: MPS6.VA15 Opis produktu Za\u015blepka zaworu Secondary Pressure Regulator Valve przeznaczona do automatycznej,","_links":{"self":[{"href":"https:\/\/automatyczni.sklep.pl\/en\/wp-json\/wp\/v2\/product\/52463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/automatyczni.sklep.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/automatyczni.sklep.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/automatyczni.sklep.pl\/en\/wp-json\/wp\/v2\/media\/52461"}],"wp:attachment":[{"href":"https:\/\/automatyczni.sklep.pl\/en\/wp-json\/wp\/v2\/media?parent=52463"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/automatyczni.sklep.pl\/en\/wp-json\/wp\/v2\/product_brand?post=52463"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/automatyczni.sklep.pl\/en\/wp-json\/wp\/v2\/product_cat?post=52463"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/automatyczni.sklep.pl\/en\/wp-json\/wp\/v2\/product_tag?post=52463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}